How a large door moves is part of how it is engineered.
Its size, weight and configuration all affect the operating system. So do the number of times it needs to open and close, the environment around it and what is moving through the opening.
OpenX considers automation and controls as part of the complete door system, alongside the structure, mechanical design and the way the door needs to work.
For a new door, replacement or upgrade, it starts with understanding the application.
START WITH HOW THE DOOR NEEDS TO WORK
Not every large door needs to operate in the same way.
A hangar door that opens a few times a week has very different demands from an industrial door operating throughout the day. A door on a remote mining site brings another set of conditions again.
Before looking at controls or automation, we look at the door itself and what is happening around it.
How large is the opening? How frequently will the door move? Who will operate it? What needs to pass through it? What conditions will the system be exposed to?
These are the things that shape how the door should operate.
WHAT WE CONSIDER
THE DOOR
The size, weight, configuration and movement of the door.
THE OPERATION
How frequently the door will move, who will operate it and how the opening is used.
THE ENVIRONMENT
Wind, dust, exposure, temperature and other conditions the system needs to work in.
THE CONTROLS
How the door needs to be operated and what level of control is required.
SAFETY
How people, vehicles, aircraft and equipment interact with the opening while the door is moving.
THE LONG TERM
Access for inspection and maintenance, component availability and how the use of the opening may change over time.
AUTOMATION IS PART OF THE DOOR SYSTEM
On a large door, the operating system and the physical door need to work together.
The system needs to control the movement of a large structure through every opening and closing cycle.
As doors become wider, taller and heavier, that relationship becomes more important.
That’s why we consider the operating system alongside the structural and mechanical design rather than treating automation as something to add once the door has been designed.
The way the door needs to move is part of the engineering from the beginning.
SAFETY AROUND A MOVING DOOR
Large doors move through spaces that can also be occupied by people, vehicles, aircraft and equipment.
How those movements interact needs to be understood when the door and its controls are designed.
The requirements will vary considerably between a hangar, workshop, mining facility and specialised application.
For that reason, safety isn’t considered separately from operation. It forms part of understanding how the complete door needs to move and be controlled.
MANUAL, POWERED OR AUTOMATED?
Automation isn’t necessary for every large door.
How the door should operate depends on its size and configuration, how frequently it will be used and what the opening needs to do.
For some applications, a simpler operating method may be the right fit. For larger doors, higher operating frequencies or more complex applications, powered or automated operation may be more appropriate.
The decision starts with the application rather than the technology.
UPGRADING AN EXISTING LARGE DOOR
The way a door needs to operate can change during its working life.
The facility may be used differently. Operating frequency may increase. Existing controls may become difficult to maintain or components may become obsolete.
Depending on the condition of the door, selected controls or operating components may be able to be upgraded without replacing the complete system.
Before making that decision, we look at the existing door as a whole.
Its configuration, mechanical components, structure, controls and current condition all affect what can practically be changed.
AUTOMATION AS PART OF A DOOR REPLACEMENT
Replacing an existing door is also an opportunity to reconsider how it operates.
The new system doesn’t necessarily need to work in the same way as the one being removed.
Changes to aircraft, equipment, workflow, frequency of use or the wider facility may mean the operating requirements have changed too.
By looking at the door, building and operation together, the controls can be developed around what the opening needs to do now and into the future.
DIFFERENT APPLICATIONS NEED DIFFERENT APPROACHES

AVIATION
Hangar door controls need to reflect the size and configuration of the door, aircraft movements and the way the hangar operates.
The door and its operating system are considered together rather than as separate parts of the project.

INDUSTRIAL & LOGISTICS
Where a large door forms part of regular vehicle, equipment or material movements, frequency of use and workflow become important considerations in how the door operates.

MINING
Large openings, heavy equipment, dust, exposure and remote locations can all affect the operating system and how it needs to be accessed and maintained.

DEFENCE & SPECIALISED FACILITIES
Where the application brings more specific access, operating or control requirements, these need to be understood alongside the door, building and wider facility.
THINKING BEYOND DAY ONE
Controls and operating components will need to be inspected and maintained throughout the working life of the door.
That makes access, maintainability and component availability worth considering during design, not later.
The use of the building may change too.
Understanding what is likely to change can help inform how the door and its operating system are configured from the beginning.
It’s part of engineering the door for the application rather than simply getting it moving
FREQUENTLY ASKED QUESTIONS
Can large industrial doors be automated?
Yes. Large industrial doors can incorporate powered or automated operation depending on the door and application. The size, configuration, frequency of use and way the opening operates all need to be considered.
Can aircraft hangar doors be automated?
Yes. The appropriate operating system depends on the hangar door configuration, opening size, aircraft movements and how the hangar is used.
Does every large door need automation?
No. Automation should suit the application. For some doors, a simpler operating method may be appropriate. Others may benefit from powered or automated operation because of their size, frequency of use or operating requirements.
Can an existing large door be automated?
Potentially. The existing door should first be assessed to understand its condition, mechanical system and controls before determining whether an automation upgrade is practical.
Can the controls on an older door be upgraded?
Depending on the system and its condition, selected controls or operating components may be able to be upgraded without replacing the complete door.
What happens if the controls on an older door become obsolete?
The existing system needs to be assessed to understand what is still serviceable and what replacement components or upgrade options are available. For older systems, it may also be worth considering the condition of the complete door before investing in a control upgrade.
Should automation be considered when the door is being designed?
Yes. The operating system affects how the door moves and interacts with the wider system. Considering it during design allows the structural, mechanical and control requirements to be developed together.
PLANNING HOW A LARGE DOOR NEEDS TO OPERATE?
OpenX considers the door, operating system and controls together.
For a new door, replacement or upgrade, understanding how the opening will be used early gives us the information needed to engineer the system around the application.